The automatic fire sprinkler system is the most widely used fire protection system today. The whole philosophy of sprinklers is based upon the premise of applying the right amount of water (as little as possible) in the right place (the seat of the fire) at the right time (as quickly as possible). Many ordinary hazard systems used to be fed directly from the town’s mains, but increasingly a water tank and pumps are being installed to guarantee adequate water flow and pressure.
The fire sprinkler system is constantly charged with water under pressure, which holds the fire sprinkler valve in the closed position. When a fire sprinkler head is activated water instantly flows on to the fire. A wet fire sprinkler system is commonly installed in areas where the ambient temperature is above 32 degrees F.
Used where a frost risk may arise, the dry fire sprinkler system is constantly charged with compressed air, which holds the fire sprinkler valve in closed position. When a fire sprinkler head is activated, the air pressure is lost, the valve opens and water flows into the system and on to the fire. A dry fire sprinkler system is commonly installed in areas where the ambient temperature is at or below 32 degrees F.
A combination of an electrical/mechanical detection system, charged with compressed air, sprinkler pipes are only filled with water upon electrical detection to avoid accidental water damage. A pre-action fire sprinkler system is commonly installed in high-risk areas such as data processing facilities or cold storage warehouses.
A combination of an electrical/mechanical detection system, fire sprinkler heads are open and the pipe is not pressurized. When the detection system is activated water discharges through all of the sprinkler heads in the system. A deluge fire sprinkler system is commonly installed in high-risk areas such as power plants, aircraft hangars, and chemical storage or processing facilities.
Absolutely not. It takes actual heat to set off a sprinkler.
It is possible for a sprinkler to discharge accidentally, but this is an extremely rare occurrence in systems which are properly maintained. Records indicate that only 1 in 16,000,000 sprinklers per year will open accidentally.
Fire department hoses typically discharge ten to a hundred times more water than that discharged by sprinklers. Since only the sprinkler closest to the fire is activated, the total amount of water is limited. Fire damage is also limited; most fires are put out quickly, by only a few sprinklers, in areas with a fully functional sprinkler system.
Most importantly, have your system periodically inspected by a professional. This will catch any problems before they become major. In addition, maintenance will usually lower insurance premiums.
No. Each sprinkler head works independently from the others and is activated by a heat only sensitive mechanism. Only the sprinkler over the fire will activate. Should the fire continue to spread, then and only then will another sprinkler activate. In most home fires, only one or two sprinklers are actually triggered. Burnt toast or smoke will not activate a sprinkler, only heat in excess of approximately 68oC/155oF.